Datasheet
No user adjustments – Adaptive Digital Logic (ADL
)
1
provides
revolutionary self-learning capability.
Continuous automatic internal adjustment of sensing threshold and drift
compensation.
Registration accuracy of ± 0.3 mm (0.012") typical at web speeds up to
1.5 m per second (5 ft per second)
Reliably detects the presence of most types of labels on web backing
Clear labels on an opaque backing
Clear labels on a clear backing
Opaque labels on an opaque backing
Opaque labels on a clear backing
Perfect for label-registering applications, and also for label-counting tasks
in slitting or rewinding applications.
Heavy-duty metal housing, 1 mm (0.04") slot
Model Number
Supply Voltage Cable Output Type User Adjustments
SLC1BB6
10 to 30 V dc
5-wire 2 m (6.5 ft)
Bipolar (NPN and PNP) None Required
SLC1BB6Q 5-pin Euro-style (QD)
To order the 9 m (30 ft) cable models, add the suffix “W/30” to the model number of the cabled version (e.g., SLC1BB6
W/30). A model with a QD connector requires an accessory mating cable.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Overview
1
2
3
4
Figure 1. SLC1 Label Sensor Features
1. Green power LED
2. Amber output LED
3. 1 mm (0.04 inch) slot
4. Web alignment guides
The SLC1 Series Label Sensor was developed to provide trouble-free
detection of labels on web backing material. It reliably senses the
difference between materials of extremely low visual contrast, including
clear labels on clear or opaque backing. The SLC1 uses Banner’s
exclusive Adaptive Digital Logic (ADL
) to automatically make all sensor
settings; no user adjustments are necessary.
NOTE: Labels with metallic inks, foil embossing or
metal substrates are not recommended for use with
SLC1 Series sensors.
1
Patent pending
C-GAGE SLC1 Series Label Sensor
Original Document
59369 Rev. B
20 March 2014
59369
Vue de la page 0
1 2 3 4 5 6

Résumé du contenu

Page 1 - Datasheet

Datasheet• No user adjustments – Adaptive Digital Logic (ADL™)1 providesrevolutionary self-learning capability.• Continuous automatic internal adjustm

Page 2 - Less Repeatability

Installing the SLC1 Series Label SensorFigure 2. Allowing the web to glide over the bottom fork with slighttension lessens the effects of web flutter.

Page 3 - Maintenance

Reset ProcedureFigure 4. For best repeatability, align the labels' flat sides betweenthe sensor's web alignment guidesResets are performed a

Page 4 - Specifications

Wiring DiagramsOutputs ON during gap (Turn OFF at leading edge oflabel)Outputs ON during label (Turn ON at leading edge oflabel)bnwhbu+–bkgy*LoadLoad1

Page 5 - Dimensions

DimensionsRemove 4 screws for cleaning.Use 7/64" hex keyClearance forM4 (#8) screws(2 holes)10.2 mm(0.40")25.4 mm(1.00")3.8 mm(0.15&quo

Page 6

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS ORIMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCH