Banner Universal Input Safety Modules Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Machines spéciales Banner Universal Input Safety Modules. Banner Universal Input Safety Modules User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 15
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
For 24V ac/dc operation, solid-state or relay inputs
Monitors a wide variety of safety and non-safety input devices:
Optical-based safeguarding devices, such as Safety Laser Scanners
Positive-opening safety switches used for guard interlocking
Emergency-stop devices, such as palm buttons and rope/cable pulls
Standard sensors for non-safety applications, such as photoelectric monitoring position
or end-of-travel.
The safety inputs can monitor:
+24V dc solid-state (PNP) outputs in single-channel or dual-channel hookup
+24V dc source that is switched by hard/relay contacts in single-channel or dual-chan-
nel hookup
Hard/relay contacts in a dual-channel hookup using terminals S11-S12 and S21-S22
UM-FA-9A: Three normally open (N.O.) output switching channels for connection to con-
trol-reliable power interrupt circuits
UM-FA-11A: Two normally open (N.O.) and one normally closed (N.C.) output switching
channels for connection to control-reliable power interrupt circuits
Automatic reset or monitored manual reset, depending on hookup
Design complies with standards ANSI B11.19 Control Reliability, ISO 13850 (EN418), and
ISO 13849-1 (EN954-1) Category 4
Safety Integrity Level SIL 3 per IEC 61508/IEC 62061
Category 4 Performance level PL e per ISO 13849-1
For use in functional stop category 0 applications per ANSI NFPA 79 and IEC/EN 60204-1
Plug-in terminal blocks
24V ac/dc operation
Models Output Switching Channels Safety Output Contact Rating
UM-FA-9A 3 normally open (N.O.) 6A
UM-FA-11A 2 normally open (N.O.), and 1 normally closed (N.C.) 7A
WARNING: Not a Safeguarding Device
This Banner device is considered complementary equipment that is used to augment safeguarding that
limits or eliminates an individual's exposure to a hazard without action by the individual or others. Failure
to properly safeguard hazards per a risk assessment, local regulations and relevant standards
could lead to serious injury or death.
Important... Read This Before Proceeding
The user is responsible for satisfying all local, state, and national laws, rules, codes, and regulations relating to the use of this
product and its application. Banner Engineering Corp. has made every effort to provide complete application, installation, operation, and
maintenance instructions. Please direct any questions regarding the use or installation of this product to the factory applications depart-
ment at the telephone numbers or address found at http://www.bannerengineering.com.
The user is responsible for making sure that all machine operators, maintenance personnel, electricians, and supervisors are thorough-
ly familiar with and understand all instructions regarding the installation, maintenance, and use of this product, and with the machinery it
controls. The user and any personnel involved with the installation and use of this product must be thoroughly familiar with all applicable
standards, some of which are listed within the specifications. Banner Engineering Corp. makes no claim regarding a specific recommen-
dation of any organization, the accuracy or effectiveness of any information provided, or the appropriateness of the provided information
for a specific application.
UM-FA-xA Universal Input Safety Modules
P/N 141249_web
Rev. E
5/28/2013
Vue de la page 0
1 2 3 4 5 6 ... 14 15

Résumé du contenu

Page 1 - 5/28/2013

For 24V ac/dc operation, solid-state or relay inputs• Monitors a wide variety of safety and non-safety input devices:• Optical-based safeguarding devi

Page 2 - Overview

WARNING: Reset Routine RequiredU.S. and international standards require that a reset routine be performed after clearing the cause of astop condition

Page 3 - Indicators and Adjustments

Checkout ProceduresCAUTION: Disconnect Power Prior to CheckoutBefore performing the initial checkout procedure, make certain all power is disconnected

Page 4 - Mechanical Installation

Periodic CheckoutThe functioning of the Safety Module and the device(s) connected to it must be verified on a regular periodic basis to ensure propero

Page 5 - Electrical Installation

Low Current RatingThe 5 μm gold-plated contacts allow the switching oflow current/low voltage. In these low-power applica-tions, multiple contacts can

Page 6

Dimensions Certifications and StandardsEC Declaration of Conformity (DOC)Banner Engineering Corp. herewith declares that the UM-FA-9A and UM-FA-11A U

Page 7 - Auto Reset

Banner Engineering Corp Limited WarrantyBanner Engineering Corp. warrants its products to be free from defects in material and workmanship for one yea

Page 8

OverviewThe UM-FA-xA Universal Safety Module (or "Safety Module" or "Module" in this document) is used to increase the safety circ

Page 9 - Automatic Reset Mode

Indicators and AdjustmentsThe Safety Module has indicators for input power and output relay contact status (K1 and K2); see Figure 1. Features on page

Page 10 - External Device Monitoring

contacts rated for safety. In addition, the switches must be mounted in a "positive mode," to move/disengage the actuator from its homeposit

Page 11 - Checkout Procedures

Electrical InstallationWARNING: Shock Hazard and Hazardous EnergyAlways disconnect power from the safety system (for example, device, module, interfac

Page 12 - Specifications

It is recommended that in all circumstances the installation of the Safety Module and its associated safety input devices are installed toeliminate or

Page 13

ResetA2(No Connection)A1S34S11S33MSC1 MSC2 MSC3S22S12S210V+24V ac/dcUM-FA-..AManual ResetDevices with relay output contactsDevices with positive-openi

Page 14 - Certifications and Standards

Auto ResetA2A1S21S11S12S220VUM-FA-..ASee Interfacing MSCsWARNINGMSC1 MSC3MSC2MSCMonitorContactsorJumperS33S34+24V ac/dc+24V ac/dcDevices with relay ou

Page 15

**L2MSC1MSC2MachineMaster StopControl Elements*Arc suppressors (see WARNING)K1A6A max.6A max.6A max.K2AK1BK2BK1CK2C*MSC313 1423 2433 34L1MachineContr