P/N 43298 rev. E 37
Banner Engineering Corp. •Minneapolis,MNU.S.A.
www.bannerengineering.com•Tel:763.544.3164
MINI-ARRAY
®
InstructionManual
System Operation
6.3 Diagnostics Program
Emitterorreceiverproblemsmaybefurtherdiagnosedusingthediagnosticsroutine,
whichisincludedwiththeMINI-ARRAYsoftware.Launchtheprogrambyselecting
Diagnostics...undertheMINI-ARRAYmenu(seeFigure6-3),orpresstheF2key.
TheDiagnosticsscreen(Figure6-4)displaysthetypeofeachemitterandreceiver
module(Board)anditsfunctionalstatus(State).Ifanerrorhasoccurred,thespecific
problembeam(Channel)willbeidentified.Additionally,Ifthereisaproblemwithan
emitterorreceivercableconnection,a“NoResponse”messagewillbedisplayed.
TheDiagnosticsroutinealsodisplaysthepartnumberanddatecodeofthecontroller,
whichmaybeusefulinformationiffactory-assistedtroubleshootingbytelephoneis
required.
Figure 6-3. MINI-ARRAY software: Main Menu
Figure 6-4. MINI-ARRAY software: Diagnostics screen