ControlLogix packing format is used to store characters into registers when the Character String
Order option is set to “Low Byte – High Byte” selection.
Please note that in this particular case, the length of the string is still stored in one 16-bit register,
and only the order of characters in each 16-bit register follows the ControlLogix format:
6.2.2 Remote Command Channel Configuration
This section describes the commands that are supported to communicate with a Vision sensor. All commands
are case-insensitive
Remote Command Set
All RCC commands are case-insensitive. Valid characters for commands are 7-bit ASCII alphabetic or numeric
characters (A-Z, a-z, 0-9), dash (-) and underscore (_).
All commands have the following structure:
ACTiON OBJECT_IDENTIFIER QUALIFIER(S)