7 – Operating Procedure
DPN 402197 © TSS (International) Ltd Page 19 of 30
7.4 AFTER THE SURVEY
To maintain the 350 System in good condition you should perform the following
important tasks after you complete the survey and recover the ROV:
❐ Print the System configuration details again. Select File➥Print Configuration in the
DeepView toolbar to send a copy of the 350 System details to the Windows™
Notepad application. Save the printed copy with the survey records.
❐ Recover the ROV.
❐ Close the internal and external log files and create backup copies of them. Include
a copy of the external log file with the survey records.
❐ Power-off the 350 System.
❐ Use a fresh water hose to wash salt and debris off the ROV-mounted components
of the 350 System. Inspect all components, cables and connectors of the installa-
tion carefully and make any repairs necessary.
❐ Check the contents of the field support kit and order any parts needed to replenish
it.