A – Operating Theory
DPN 402197 © TSS (International) Ltd Page 5 of 10
You may pass measurements made using any available mode to an external data
logger for subsequent analysis.
See Sections 5 and 6 for a description of the SDC software. Refer to Section 7 for
instructions to use the 350 System during a survey.
A.4.1 Survey Mode
To measure the target co-ordinates (vertical range and lateral offset), the 350 System
uses signals from only the vertical and the lateral sensing coils in each coil triad.
Given a known frequency and magnitude of current in the conductor, the amplitude of
signal voltage delivered by each coil winding will depend upon the relative angle
between the coil and the conductor.
Figure A–4: The effect of incident angle on coil response
Figure A–4 shows the cross-section of a conductor carrying an alternating current
that has a constant peak amplitude and frequency.
Figure A–5: Coil response as incident angle varies