Banner DF-G1-PR-Q7 Instructions d'exploitation Page 81

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 253
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 80
350 Cable Survey System
DPN 402197 © TSS (International) Ltd Page 2 of 32
6.1 CONFIGURATION
TSS (International) Ltd has designed the 350 System and Deepview for Windows to
be easy to use. A System Configuration Wizard guides you quickly through the proce-
dure to choose the SEP type and communication parameters. However, some impor-
tant parameters must be entered before the survey can begin.
6.1.1 Survey Parameters
To follow we have listed some key parameters that will be required to be set prior to
and during the survey. Details of setting these parameters are covered in the software
details in section 6.2.
Configure the 350SEP with the following information:
6.1.1.1 Tone Frequency
Set this value to the same frequency as that present on the cable. The range is from
zero to 200Hz. This value must be set accurately, or the system will not find the tone.
6.1.1.2 Threshold
Set an appropriate value for threshold.
High settings will make the 350 System less sensitive to noise but will also decrease
its operating range. The default setting of 100µV has proved to be suitable for the
majority of survey operations.
If you are in any doubt about threshold, leave the setting at its default value.
6.1.1.3 Coil Separation
Section 3.2.2 explains how to install the two coil triads on the ROV and adjust the
separation distance. Enter the separation distance in cm. The accuracy of the survey
depends on this parameter being entered correctly.
6.2 DEEPVIEW FOR WINDOWS OPERATING CONTROLS
TSS (International) Ltd has designed DeepView for Windows to provide full function-
ality when you use a pointing device, such as a mouse or the supplied trackball, to
select commands and controls. You may also access many software features by
using the SDC keypads.
The instructions that follow assume you to be reasonably familiar with the Microsoft
Windows operating environment. If necessary, refer to a relevant Windows user guide,
such as the one that accompanies the SDC, for instructions to use Windows.
6.2.1 How to Use DeepView for Windows
This sub-section explains how to use the software commands and tools during a sur-
vey. The instructions refer to the Run Window and to the various secondary windows
described throughout this section. DeepView includes an on-line Help structure that
summarises the advice and instructions included here. There is also a simple ‘Help’
panel, accessible by pressing function key [F1] from the Run Window, to list the func-
Vue de la page 80